Features
- Continuous, alphanumeric LCD shows detector life remaining, alarm setpoints and advises self-test status
- Rugged, IP-66/67 highly water-resistant design
- Two years of protection with zero maintenance costs
- Built-in concussion-proof boot
- Records and displays the peak alarm encountered and the time since the exposure occurred
- Records and transmits gas alarm events encountered and the time elapsed since the event occurred
- Provides typical 95 dB tone and bright, quad-LED indication on alarm
- Internal vibrator alarm
- Small size (1.1 x 2.0 x 3.2 in. / 28 x 50 x 81 mm) and lightweight (2.7 oz. / 76 g)
- Maintenance free—no sensor or battery replacement, no calibration, no downtime
- Two alarm levels (Low / High)
- Full function self-test of: audible/visual alarms plus integrity of sensor, battery and circuitry
- Continuously ON—one button activation, test and data transmission
- Comes complete with pocket/belt clip and test cap
- Instructions in local languages included
- Optional alligator and hard hat clips available
Supported Gases:
- H2S - hydrogen sulfide
- O2 - oxygen
- CO - carbon monoxide
- SO2 - sulfur dioxide
Description
GasAlertClip Extreme 2 Detector - Hydrogen sulfide (H2S), Low - 10 ppm / High - 15 ppm
As the world’s most popular and widely used zero-maintenance gas detector, the GasAlertClip Extreme offers continuous, reliable protection. Available in two year or three year versions, this single gas detector requires no calibration, sensor replacement, battery replacement, or battery charging. Compatible with the MicroDock II automatic test system, the simplicity of the GasAlertClip Extreme combined with minimal training requirements and negligible maintenance costs, make the GasAlertClip Extreme one of the most cost-effective PPE solutions for facility workers and on-site contractors.
The remaining life of the detector is displayed in months, days, then hours. A full function self-test verifies sensor, circuitry and battery integrity as well as function of the audible, visual and vibrator alarms. Stored data can be transmitted directly by IR link to a cordless infrared printer for immediate printout, or to a personal computer by means of an IR adapter connected to the computer’s USB port.
The GasAlertClip Extreme has two alarm setpoints used to activate a high output 95 dB (typical) audible alarm, a bright, wide-angled quad LED visual alarm and a built-in vibrator alarm.
Models, Options, & Accessories
Model
|
Description
|
GA24XT-H
|
GasAlertClip Extreme 2 Detector - Hydrogen sulfide (H2S), Low - 10 ppm / High - 15 ppm
|
GA24XT-H-B50
|
GasAlertClip Extreme 2 Detector - Hydrogen sulfide (H2S) - Bulk Pack*, Low - 10 ppm / High - 15 ppm
|
GA24XT-H510
|
GasAlertClip Extreme 2 Detector - Hydrogen sulfide (H2S), Low - 5 ppm / High - 10 ppm
|
GA24XT-H510-B50
|
GasAlertClip Extreme H2S w/ eventlogging, vibrator, 5/10 , 2 year, bulk order of 50 units
|
GA24XT-M
|
GasAlertClip Extreme 2 Detector - Carbon monoxide (CO), Low - 35 ppm / High - 200 ppm
|
GA24XT-M30200
|
GasAlertClip Extreme 2 Detector - Carbon monoxide (CO), Low - 30 ppm / High - 200 ppm
|
GA24XT-M50200
|
GasAlertClip Extreme 2 Detector - Carbon monoxide (CO), Low - 50 ppm / High - 200 ppm
|
GA24XT-S
|
GasAlertClip Extreme 2 Detector - Sulfur dioxide (SO2), Low - 5 ppm / High - 10 ppm
|
GA24XT-X
|
GasAlertClip Extreme 2 Detector - Oxygen (O2), Low - 19.5% / High - 23.5%
|
GA24XT-X19.522.5
|
GasAlertClip Extreme 2 Detector - Oxygen (O2), Low - 19.5% / High - 22.5%
|
Model
|
Accessories
|
GA24-BALERT
|
Concussion-proof boot with stainless steel alligator-style clip For GasAlert Clip Extreme Series
|
GA-AG-1
|
Alligator-style clip (non-conductive) For GasAlert Clip Extreme Series
|
GA-AG-2
|
Alligator-style clip (stainless steel) (included with detector) For GasAlert Detectors
|
GA-CL-1
|
Belt clip with screw For GasAlert Extreme & Clip Extreme Series
|
GA-ES-1
|
Extension strap (4 ft. / 1.2 m) For GasAlert Extreme Series
|
GA-HC-1
|
Hard hat clip (non-conductive) For GasAlert Extreme & Clip Extreme Detectors
|
GA-NS-1
|
Neck strap with safety release For GasAlert Series
|
GA-TC-1
|
Test cap and hose (1 ft. / 0.3 m) replacement (included with detector)
|
GA-USB2
|
IR datalink USB adaptor
|
GA-BSPLASH-K
|
Splash guard filters, kit of 5 for use with concussion-proof boot (GA-BALERT) For GasAlert Detectors
|
Specifications
Gas monitored
|
H2S
|
CO
|
SO2
|
O2
|
Sensor range
|
0 - 100 ppm
|
0 - 300 ppm
|
0 - 100 ppm
|
0 - 30.0% by vol.
|
Low alarm level
|
10 ppm
|
35 ppm
|
5 ppm
|
19.5 %
|
High alarm level
|
15 ppm
|
200 ppm
|
10 ppm
|
23.5 %
|
Operating Temperature
|
-40 to +122 °F -40 to +50 °C
|
-22 to+122°F -30 to +50°C
|
-22 to +122 °F -30 to +50 °C
|
-4 to +122 °F -20 to +50 °C
|
Calibration
|
Not required
|
Self-calibrating
|
|
|
General Specifications
|
Rugged composite material with integral concussion-proof boot
|
Humidity
|
5% to 95% RH (non-condensing)
|
EMI/RFI
|
Complies with EMC Directive 89/336/EEC
|
Ingress protection
|
IP 66/67
|
Battery
|
Lithium, non-replaceable
|
Size
|
28 x 50 x 81 mm / 1.1 x 2.0 x 3.2 inches
|
Weight
|
76 g / 2.7 oz.
|
Warranty
|
2 years from activation plus 1 year shelf-life
|
Operational life
|
Two years3
|
Continuously on
|
Yes
|
One-button control
|
Activation, self-test and alarm event data transmission
|
Full function self-test
|
Verifies integrity of sensor, circuitry and battery; audible/visual alarms
|
Sensor
|
Electrochemical cell (temperature compensated)
|
Indicactors And Alarms
|
Visual gas alarm
|
Flashing, wide-angled alarm lens with dual red LEDs plus ALARM LCD readout
|
Audible gas alarm
|
Pulsing siren 85 dB at 0.3 m / 1 ft.
|
Vibrator alarm
|
Internal
|
Failure alarm
|
Yes (audible/visual)
|
Self-test pass
|
Yes (audible/visual)
|
Other
|
Low battery and end of life (audible/visual)
|
Continuos LCD Display
|
Alphanumeric status panel LCD advises
|
Life remaining
|
Continuously displayed in months, then days, then hours
|
Two alarm levels
|
LOW alarm / HIGH alarm
|
Peak alarm exposure
|
Records and displays peak alarm exposure, and time elapsed (up to 24 hrs.)
|
Alarm setpoints
|
High and low (displayed on demand in ppm or %)
|
Self-test status
|
Advises to “TEST” and that self-test was passed “.”
|
Tests
|
Full function self-test
|
On-demand, as often as once every 20 hours and on activation
|
Battery
|
Every two hours (auto)
|
Event Logging
|
Records and transmits up to 10 gas alarm events
|
Event information
|
Gas type, peak exposure level (ppm or %); alarm duration in minutes and seconds; time elapsed since the alarm occurred in days, hours and minutes
|
Transmission method
|
Via infrared port to thermal printer or USB
|
|